Shimano error code E031 indicates an internal sensor initialization failure or drive circuit fault, most often caused by improper crank position, incorrect chain tension, or an initialization error during startup. On Shimano STEPS drive units paired with internal gear hubs and automatic shifting setups, the system monitors chain tension and crank angle sensors before engaging assist. If these internal circuits detect physical binding, an irregular crank mounting angle, or an electrical supply abnormality across the sensor board, E031 is triggered and assist is shut down.
Fast Fix
Turn off the bike, dismount completely, and take all weight off the pedals. Verify that the crank arms are firmly attached and aligned exactly 180 degrees apart. Check that the chain is not excessively slack or overly tight. Power the bike on without touching the pedals, cranks, or drivetrain.
Quick Status & System Impact
- Severity: Medium to High. Assist functions are disabled to prevent damage to internal torque and position sensors.
- Rideability: The bike can be pedaled manually, and electronic gear shifting usually remains functional, but motor assist will not engage.
- Primary Cause: Incorrect crank arm installation position, out-of-spec chain tension, foot pressure on the pedals during system startup, or an internal circuit failure within the drive unit’s sensor array.
Diagnostic Path: Identifying the Mechanical vs. Electrical Trigger
- Code appears only when turning the bike on: This strongly points to a startup initialization error. Resting your foot on a pedal or applying torque while pressing the power button throws off zero-point calibration, producing an internal sensor circuit error.
- Code appeared after replacing cranks, chain, or chainring: The crank arms were installed at an incorrect relative offset, or a single-speed/internal-hub chain was tensioned too tightly, pulling the drive axle out of its calibrated resting threshold.
- Code appears intermittently under heavy load: If chain tension is normal, intermittent E031 errors suggest micro-flexing in the crank spindle assembly or a failing internal circuit board inside the drive unit.
Likely Mechanical and Electrical Causes
1. Startup Torque Sensor Disturbance
Shimano STEPS systems run an automated self-test on internal sensor circuits the second power is turned on. If the internal circuit detects resistance or spindle movement before the operating system stabilizes, it trips a sensor fault.
2. Crank Installation Angle and Chain Tension
On systems utilizing cadence and position monitoring for automatic shifting (such as E6000/E6100 with Di2 hubs), the drive unit relies on precise crank angle detection. If the left and right crank arms are not positioned exactly opposite one another (180 degrees), or if an eccentric bottom bracket or sliding dropout pulls the chain so tight that the spindle experiences static preload, the sensor circuit flags an out-of-range signal.
3. Moisture Ingress or Circuit Degradation
If the bike was washed with high-pressure water or ridden in deep standing water, moisture can bridge sensitive circuit traces on the internal drive board, creating signal noise that the controller interprets as a circuit breakdown.
Step-by-Step Resolution
Step 1: Perform a Clean Zero-Point Restart
- Stop the bike on level ground and turn the power off.
- Step off the bike completely. Ensure nothing is leaning against the crank arms or pedals.
- Press the power button once. Do not touch the pedals or drivetrain until the main display screen completely loads and displays the standard ride data.
Step 2: Check Crank Arm Alignment
- Inspect the left and right crank arms. They must be mounted directly opposite each other on the splined spindle.
- If a crank arm was recently replaced or removed for service, verify that it was not installed off-spline.
- Ensure both crank pinch bolts are torqued evenly to the manufacturer specification (typically 12–14 Nm for Shimano hollow-tech style crank arms).
Step 3: Inspect Drivetrain and Chain Tension
- On bikes equipped with internal gear hubs, check chain or belt tension. A chain should have roughly 10–15 mm of vertical deflection at the midpoint between the chainring and rear cog.
- A rock-hard, over-tensioned chain places excessive lateral preload on the drive unit’s internal bottom bracket bearings and torque sleeve, preventing proper circuit calibration. Loosen the rear wheel axle nuts or chain tensioner slightly to restore correct slack.
- If a “W031” question prompt appears on your display after power-up asking if chain tension was adjusted, select Yes to allow the system to re-initialize.
Step 4: System Diagnostic Check
If mechanical factors have been ruled out, connect the bike to Shimano E-TUBE PROJECT. Check the error log for related faults such as E012 (torque sensor calibration) or general system errors. For broader system troubleshooting, see Shimano Error E010: System Error Troubleshooting.
Repair and Escalation Context
If E031 refuses to clear after verifying correct crank orientation, chain tension, and hands-free startups, the fault resides within the internal circuit board or the internal torque/cadence sensor assembly inside the motor. Shimano drive units are sealed, non-serviceable units for end users. Opening the casing voids the warranty and compromises weather seals. Persistent internal circuit faults require motor replacement or warranty exchange through an authorized dealer.